Essays about: "detector calibration"

Showing result 1 - 5 of 51 essays containing the words detector calibration.

  1. 1. Analysis of fatty acids in fatty acid-based herbicides by gas chromatography

    University essay from Lunds universitet/Kemiska institutionen

    Author : Mohamad Abd Elwadood; [2023]
    Keywords : Analytical Chemistry; Fatty Acids; Gas Chromatography; Green Herbicides; Retention Index; Flame Ionization Detector; Mass Spectrometry; Supercritical Carbon Dioxide Extraction.; Chemistry;

    Abstract : Fatty acids-based herbicides are considered to be a green alternative to synthesized weed control products. However, the environmentally sustainable effect of those herbicides needs more investigation to be confirmed. READ MORE

  2. 2. Quality Assessment of the Fabry-Pérot Wavelength Calibration for CRIRES+ : Student Project Report

    University essay from Uppsala universitet/Observationell astrofysik

    Author : Christopher Borchert; [2023]
    Keywords : ;

    Abstract : The data reduction software of CRIRES+, a new high-resolution spectrometer installed at VLT, features a calibration routine that uses data from a Fabry-Pérot étalon. The quality of this calibration mode is assessed in this project report. READ MORE

  3. 3. Developments Towards High-Resolution Muonic Atom X-ray Spectroscopy of Low-Z Elements : For precision measurements of absolute nuclear charge radii

    University essay from Uppsala universitet/Högenergifysik

    Author : Benjamin Verbeek; [2023]
    Keywords : muon physics; subatomic physics; charge radius; nucleus; lithium; silicon drift detector; microcalorimeter;

    Abstract : This Master's thesis investigates a method to measure atomic nuclei with record precision using muonic atom X-ray spectroscopy. In particular, 6Li is measured experimentally. The method used is independent from the previous most precise measurement of the 6Li nuclear charge radius which uses electron scattering. READ MORE

  4. 4. Calibration and preparation of the data analysis of the DORN experiment on board the Chang'E 6 lunar mission.

    University essay from Luleå tekniska universitet/Institutionen för system- och rymdteknik

    Author : Íñigo de Loyola Chacartegui Rojo; [2023]
    Keywords : Radon; lunar mission; alpha spectrometry; space instrumentation; performance testing and validation;

    Abstract : As part of the first agreement between the French (CNES) and the Chinese (CNSA) space agencies in terms of space exploration, the DORN instrument will fly on board the Chinese Chang'E 6 mission in 2024. It aims to measure the amount of Radon escaping from the lunar soil to better understand what governs the concentration of this noble gas which contributes to the endogenous origin of the lunar exosphere. READ MORE

  5. 5. Optimization of Gammasphere Data Following the Nuclear Reaction 36Ar + 24Mg → 60Zn∗

    University essay from Lunds universitet/Fysiska institutionen; Lunds universitet/Partikel- och kärnfysik

    Author : Paul Böhm; [2023]
    Keywords : re-calibration; Gammasphere; 54Fe; Physics and Astronomy;

    Abstract : The experiment at Argonne National Laboratory aimed to study the fusion-evaporation reaction following the collision of a high-energy particle beam of 36Ar with a stationary target of 24Mg. This paper outlines the creation and implementation of an automated re-calibration procedure for the high-purity Germanium detectors comprising the Gammasphere array used for γ-ray spectroscopy in this experiment. READ MORE