Essays about: "winding insulation"
Showing result 1 - 5 of 13 essays containing the words winding insulation.
-
1. Allowing more solar power connected to the grid, using thermal and ageing models of distribution transformers.
University essay from Högskolan Dalarna/Institutionen för information och teknikAbstract : Increasing amounts of solar power connected to the low-voltage network will adversely affect the performance of the network. The two impacts that will most often set the limit are overvoltage with the customers and overloading the distribution transformer. READ MORE
-
2. Minimizing Transformer No-Load Losses at Hydropower Plants : A Study of Effects from Transformer Switch-Off During Stand-by Operation
University essay from Uppsala universitet/Institutionen för elektroteknikAbstract : Hydropower is the most important power balancing resource in the Swedish electrical power system, regulating the power supply to match the load. Consequently, several hydropower plants have periods of stand-by operation where the power production is absent but where several devices within a plant are still active. READ MORE
-
3. Influence of structural and materials properties on the flexural strength of laminated high-density cellulose fiberboards
University essay from KTH/HållfasthetsläraAbstract : Laminated pressboard is a structural electrical insulation material used in power transformers. Typical applications are areas in the power transformers where high mechanical forces are present such as pressrings or winding tables and cleats which support the electrical cables connecting the transformer windings to tap-changes and bushings. READ MORE
-
4. Dielectric Response and Partial Discharge Characteristics of Stator Winding Insulation System with SiC Stress Grading
University essay from KTH/Skolan för elektroteknik och datavetenskap (EECS)Abstract : The typical construction of a stator coil includes the use of end corona protection (ECP)coating, which is made of semi-conductive materials like silicon carbide (SiC). Thepurpose of ECP is to smooth the electric stress distribution near the slot exit, limitingthe electric field and partial discharge (PD) activity within the insulation system. READ MORE
-
5. Real-time detection of stator resistance unbalances in three phase drives
University essay from KTH/Skolan för elektroteknik och datavetenskap (EECS)Abstract : An estimated 30% of the faults in Induction Machine (IM) are related to its stator. These faults are mostly in the form of an Inter-Turn Short Circuit (ITSC) fault i.e., when two winding inside the stator of IM are shorted due to insulation failure. READ MORE