Mätning av egenskaper hos elmotor och transformatorplåt

University essay from Chalmers tekniska högskola/Institutionen för energi och miljö

Abstract: Core loss measurements have been done. Because of the low magnetization current of thetoroid the current was measured with a current transducer of model LA 100-S/SP1 and thevoltage was measured with a voltage probe of model TT-SI9101 for better accuracy. Theknowledge of the current and voltage made it possible to calculate the magnetic field strengthand the magnetic field density and further with that the core losses.The obtained losses did not match with the losses given by the datasheet. The reason for themismatch can be that the dimensions of the toroid core contribute in measuring the B-fieldvalue wrong.