Monitoring Kraft Recovery Boiler Fouling by Multivariate Data Analysis

University essay from KTH/Skolan för kemi, bioteknologi och hälsa (CBH)

Abstract: This work deals with fouling in the recovery boiler at Montes del Plata, Uruguay. Multivariate data analysis has been used to analyze the large amount of data that was available in order to investigate how different parameters affect the fouling problems. Principal Component Analysis (PCA) and Partial Least Square Projection (PLS) have in this work been used. PCA has been used to compare average values between time periods with high and low fouling problems while PLS has been used to study the correlation structures between the variables and consequently give an indication of which parameters that might be changed to improve the availability of the boiler. The results show that this recovery boiler tends to have problems with fouling that might depend on the distribution of air, the black liquor pressure or the dry solid content of the black liquor. The results also show that multivariate data analysis is a powerful tool for analyzing these types of fouling problems. 