Resolution Improvements and Physical Modelling of a Straw Tracker : The NA62 Experiment at CERN

University essay from Umeå universitet/Institutionen för fysik

Abstract: Lab measurements and Monte Carlo simulations have been carried out for the evaluation of the Straw-type detectors used in the NA62 experiment at CERN. In addition, analyses of experiment data was used in corrections to improve the reconstruction of particle tracks, ultimately leading to improved resolution of the detector system as a whole. 97.7 percent of the Straws were aligned to within 30 microns, quantified as the deviation from zero of the mean of the inherent residual distribution of each Straw. A drift time dependence on where along the Straw the particle ionized have been corrected for; before the correction the dependence was as big as 6 ns. A radius-drift time relation based on the leading edge timing distribution has been deduced and implemented. Upon implementation artifacts from the piecewise fits used became evident. An alternative approach using residuals has been put forward.

  AT THIS PAGE YOU CAN DOWNLOAD THE WHOLE ESSAY. (follow the link to the next page)