Essays about: "Radioactive source"
Showing result 16 - 20 of 40 essays containing the words Radioactive source.
-
16. Simulation of Anti-Compton Shield Augmentation to the Lundium Decay Station Using Geant4
University essay from Lunds universitet/Kärnfysik; Lunds universitet/Fysiska institutionenAbstract : The Lundium decay station improves on the existing TASISpec spectrometer used to investigate the nuclear structure of superheavy nuclei by photon- and charged particle-spectroscopy. This thesis aims to explore the potential benefits of the future Lundium station with the augmentation of anti-Compton shields com- posed by a set of BGO scintillator bars. READ MORE
-
17. Identification of Neutrons Using Digitized Waveforms
University essay from Lunds universitet/Kärnfysik; Lunds universitet/Fysiska institutionenAbstract : The advantages of performing neutron-tagging measurements using a waveform digitizer are explored. An existing analog setup consisting of modular crate electronics at the Source-Testing Facility at the Division of Nuclear Physics in Lund, Sweden has been digitally replicated. READ MORE
-
18. Characterization of Double Sided Silicon Strip Detectors from LYCCA modules for FAIR
University essay from Lunds universitet/Kärnfysik; Lunds universitet/Fysiska institutionenAbstract : Begun in 2010, the Lund-York-Cologne-CAlorimeter, LYCCA, collaboration is targeted at discovering exotic nuclear reaction products whilst implementing the possibility of both position tracking and measuring residual energies of relativistic particles. Each LYCCA module is composed of a double sided silicon detector and 9 CsI(Tl) detectors. READ MORE
-
19. Vanadium-based neutron-beam monitor
University essay from Lunds universitet/Kärnfysik; Lunds universitet/Fysiska institutionenAbstract : A prototype invasive (quasi-parasitic) thermal-neutron beam monitor based on isotropic neutron scattering from a thin natural Vanadium foil and standard $^3$He proportional counters has been conceptualized, designed, simulated, calibrated, and commissioned. As the beam monitor is invasive, very low neutron-beam attenuation is a necessary characteristic. READ MORE
-
20. Modelling and Simulations of a clinical PET-system using the GATE Monte Carlo software
University essay from Lunds universitet/SjukhusfysikerutbildningenAbstract : Introduction: The increased importance of PET imaging in the health care system has lead to a constant need for improvement and optimisation of scanner systems and their protocols. By utilising the features of the GATE Monte Carlo program one can gain a better understanding of the limitations and possibilities of the system. READ MORE