Advanced search

Showing result 1 - 5 of 16 essays matching the above criteria.

  1. 1. Multi-Parameter Modelling of Surface Electromyography Data

    University essay from Lunds universitet/Avdelningen för Biomedicinsk teknik

    Author : Ahmad Alosta; Josef Djärf; [2024]
    Keywords : Surface electromyography; modelling; Python; sEMG; decomposition; neuroengineering; motor unit; muscle; simulation; Technology and Engineering;

    Abstract : Ytelektromyografi (sEMG) mäter skelettmuskelfunktionen genom att registrera muskelaktivitet från hudens yta. Tekniken kan användas för att diagnostisera neuromuskulära sjukdomar och som ett hjälpmedel vid rehabilitering, biomedicinsk forskning och för interaktion mellan människa och dator. READ MORE

  2. 2. EMG-aktivering av rotatorcuffen vid olika muskelstärkande aktiviteter - En biomekanisk studie.

    University essay from Lunds universitet/Människan i rörelse: hälsa och rehabilitering

    Author : Jonatan Löf; Rasmus Lundqvist; [2022]
    Keywords : Electromyography EMG ; Rotator cuff; TheraBand; Pulley-system; Maximal Voluntary Isometric Contraction MVIC ; Medicine and Health Sciences;

    Abstract : Introduction Both M. Supraspinatus and M. Infraspinatus of the rotator cuff play a role in stabilizing the shoulder during movement. When rehabilitating shoulders after injury a wide range of tools are used to strengthen the shoulder, often including a pulley system or TheraBand. READ MORE

  3. 3. High density EMG based estimation of lower limb muscle characteristics using feature extraction

    University essay from KTH/Skolan för kemi, bioteknologi och hälsa (CBH)

    Author : Balázs Szabó; [2021]
    Keywords : HD-EMG; feature extraction; lower limb; muscle characteristics;

    Abstract : Electromyography (EMG) is a common tool in electrical muscle activity measurement and can be used in multiple areas of clinical and biomedical applications, mainly in identifying neuromuscular diseases, analyzing movement or in human machine interfaces. Traditionally a pair of electrodes were used to measure the signals, but in recent years the use of high density surface EMG (HD-sEMG) gained more popularity as it can sample myoelectric activities from multiple electrodes in an array on a single muscle and provide more information. READ MORE

  4. 4. Comparison of high density and bipolar surface EMG for ankle joint kinetics using machine learning

    University essay from KTH/Skolan för kemi, bioteknologi och hälsa (CBH)

    Author : Federica Aresu; [2021]
    Keywords : EMG; HD-sEMG; machine learning; joint torque;

    Abstract : The relationship between sEMG signals and muscle force, and associated joint torque, is an object of study for clinical applications such as rehabilitation robotics and commercial applications as wearable motion control devices. The information type and quality obtained by sEMG can impact the classification and prediction accuracy of ankle joint torque. READ MORE

  5. 5. Development of technique for measuring muscle activity and knee motion in children with CP

    University essay from Lunds universitet/Avdelningen för Biomedicinsk teknik

    Author : Hamed Rahim Zadeh; [2020]
    Keywords : Technology and Engineering;

    Abstract : Cerebral Palsy (CP) has an impact on muscles and movement. This happens due to brain damage before the age of two years. Either sometimes before birth, during childbirth or after birth. According to hjarnfonden. READ MORE